Spraybooth Extraction Chest & Fan System (DIY / Self-Installation)
A cost-effective, high-volume spraybooth extraction kit engineered for straightforward self-installation. Designed for workshops and bodyshops looking to establish compliant overspray extraction using standard ductwork fittings.
Package Includes
- Heavy-duty galvanised extract chest
- 1.1kW single-phase bifurcated axial fan unit
- Rectangular transformer duct (adapts the top of the extract chest to 600mm square ductwork)
Technical Specifications
- Chest Dimensions: 2500 (W) x 1000 (H) x 500 mm (D)
- Fan Type: Bifurcated axial fan (motor isolated outside contaminated airstream)
- Airflow Capacity: Nominal 8,500 m³/hr
- Motor Rating: 1.1 kW, 240V single phase (requires 6A supply)
- Duct Connection: Configured for standard 600mm square ducting with 20mm MEZ flanges
Installation Guide & Site Requirements
The extraction chest is supplied flat-packed or pre-assembled (top, base, sides, and face) for on-site positioning and installation. Perimeter sealing to the workshop floor is to be completed by the installer.
Because every workshop layout is unique, ancillary ductwork and roof fittings are site-dependent and sold separately. When planning your installation, ensure you account for:
- Discharge Route: Deciding whether duct runs through an external wall or through the roof.
- Weatherproofing: Weather collars, cosmetic flashing plates, or Dektite roof seals.
- Discharge Cowling: High-velocity discharge cowl or jet cowl to prevent rainwater ingress.
- Duct Supports: Wall brackets, drop rods, or exterior guy wires for vertical runs.
- Electrical Supply: Dedicated 6A single-phase supply and isolator switch connection.
- Building Penetrations: Core drilling or cladding cuts for 600mm duct penetrations.
Note: Price is for supply only and excludes VAT and delivery.
For more information call 07887 834796 or email info@filtercare.co.uk